7 Matching results
RYOBI Brad Nailer not firing or is misfiring
Remove battery for inspecting the tool. Check if there are fasteners in the magazine by dislodging the magazine latch and inspecting it. Ensure the correct gauge nails for the Nailer are being used. Check for any jams. In the event of a jam, open…
Last update: 06/02/2023, 18:27
RYOBI Airwave/Pneumatic Brad Nailer doesn't fire deep enough
If your RYOBI Airwave/Pneumatic Brad Nailer doesn't fire deep enough and the fastener is protruding, increase the air pressure by increments of 0.5 bar, checking the result after each new adjustment. It is preferred to adjust the depth adjustment…
Last update: 16/03/2023, 14:26
12.0AH battery doesn’t work when RYOBI 36V Blower turbo button is pressed
The 12.0Ah HP battery (R36BTY12) isn’t compatible with this Blower model’s turbo function. This is caused by the high output of the HP battery causing the overload protection to activate.
Last update: 29/08/2022, 09:37
What to do if 18V or 36V RYOBI Blower doesn't work
First remove and reinsert the battery to ensure that it’s seated properly in the Blower. If this doesn’t work, check the battery charge level by pushing the battery indicator button.
Last update: 14/07/2023, 11:04
How to lock & unlock a RYOBI 18V ONE+ 184mm Mitre Saw's handle
To unlock the handle of a 18V ONE+ 184mm Mitre Saw, pull down the handle and hold it there. The saw handle is locked down with a pin located on the right. Then pull the locking pin all the way out. Slowly bring up the saw handle and then check it…
Last update: 13/09/2023, 10:46
Fix a RYOBI 18V ONE+ 184mm Mitre Saw's jammed handle
If your RYOBI 18V ONE+ 184mm Mitre Saw has a jammed handle, it's possible the saw handle was pulled up or down with it's locking pin not fully in our out and is now obstructing movement. Check that the locking pin is correctly positioned either…
Last update: 13/09/2023, 10:42
RYOBI 18V ONE+ 184mm Mitre Saw's handle won't move
If your RYOBI 18V ONE+ 184mm Mitre Saw handle won't move up or down freely, don't force it as it can damage the tool. It's likely the locking pin isn't fully in or out, and is obstructing movement. Check that the locking pin is correctly positioned…
Last update: 13/09/2023, 10:44