8 Matching results
Product Safety Recall Airwave 2-in-1 C1 Brad Nailer/Stapler RA-NBS1832-S
The product that is the subject of the recall is the RYOBI RA-NBS1832-S Airwave 2-in-1 C1 Brad Nailer/Stapler. The Product has been sold through Bunnings retailers throughout Australia from 1 October 2021 – 31 March 2024. Affected products will…
Last update: 20/05/2024, 16:11
RYOBI Brad Nailer not firing or is misfiring
Disconnect the tool from the air supply before any checks and keep the tool pointed away from you. Check if there are fasteners in the magazine by dislodging the magazine latch and inspecting it. Ensure the correct gauge nails for the Nailer are…
Last update: 05/09/2024, 13:07
RYOBI Brad Nailer Brads aren’t flush
The driving depth of the fastener may need to be adjusted. Test the depth on a scrap workpiece to determine the required depth for the application. To determine depth of drive, adjust the air pressure on the tool by rotating the dial on the back of…
Last update: 05/09/2024, 13:40
RYOBI Brad Nailer jamming
Disconnect the tool from the air supply before any checks and keep the tool pointed away from you. Always ensure the correct gauge of nails is being used. We also recommend you confirm the angle required for collation nails matches that of the Nail…
Last update: 17/09/2024, 18:52
RYOBI Airwave/Pneumatic Brad Nailer doesn't fire deep enough
If the fastener is protruding, increase the air pressure by increments of 0.5 bar, checking the result after each new adjustment. It is preferred to adjust the depth adjustment knob to reach the preferred fastening effect. The amount of air pressure…
Last update: 05/09/2024, 16:43
RYOBI Petrol Blower Vacuum difficult to start
If you’re having trouble starting your RYOBI Petrol Blower Vacuum, first make sure you’re following the correct starting process. Also check for a flooded engine, stale fuel, dirty air filter/spark plug or incorrect fuel mixture. You may have also…
Last update: 26/08/2022, 10:31
RYOBI Blower Vacuum can’t switch between modes
If your RYOBI Blower Vacuum can’t switch between modes, it may be because of a build-up of debris in the lever or deep inside the elbow.
Last update: 26/08/2022, 14:33